<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Ferrari, G</style></author><author><style face="normal" font="default" size="100%">Kozarski, M</style></author><author><style face="normal" font="default" size="100%">Gu, Y J</style></author><author><style face="normal" font="default" size="100%">De Lazzari, C</style></author><author><style face="normal" font="default" size="100%">Di Molfetta, A</style></author><author><style face="normal" font="default" size="100%">Palko, K J</style></author><author><style face="normal" font="default" size="100%">Zieliński, K</style></author><author><style face="normal" font="default" size="100%">Górczynska, K</style></author><author><style face="normal" font="default" size="100%">Darowski, M</style></author><author><style face="normal" font="default" size="100%">Rakhorst, G</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Application of a user-friendly comprehensive circulatory model for estimation of hemodynamic and ventricular variables.</style></title><secondary-title><style face="normal" font="default" size="100%">Int J Artif Organs</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Int J Artif Organs</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Animals</style></keyword><keyword><style  face="normal" font="default" size="100%">Cardiac Pacing, Artificial</style></keyword><keyword><style  face="normal" font="default" size="100%">Cardiovascular Diseases</style></keyword><keyword><style  face="normal" font="default" size="100%">Elasticity</style></keyword><keyword><style  face="normal" font="default" size="100%">Hemodynamics</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Models, Cardiovascular</style></keyword><keyword><style  face="normal" font="default" size="100%">Reproducibility of Results</style></keyword><keyword><style  face="normal" font="default" size="100%">Ventricular Function</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2008 Dec</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">31</style></volume><pages><style face="normal" font="default" size="100%">1043-54</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;b&gt;PURPOSE: &lt;/b&gt;Application of a comprehensive, user-friendly, digital computer circulatory model to estimate hemodynamic and ventricular variables.&lt;/p&gt;&lt;p&gt;&lt;b&gt;METHODS: &lt;/b&gt;The closed-loop lumped parameter circulatory model represents the circulation at the level of large vessels. A variable elastance model reproduces ventricular ejection. The circulatory model has been modified embedding an algorithm able to adjust the model parameters reproducing specific circulatory conditions. The algorithm reads input variables: heart rate, aortic pressure, cardiac output, and left atrial pressure. After a preliminary estimate of circulatory parameters and ventricular elastance, it adjusts the amount of circulating blood, the value of the systemic peripheral resistance, left ventricular elastance, and ventricular rest volume. Input variables and the corresponding calculated variables are recursively compared: the procedure is stopped if the difference between input and calculated variables is within the set tolerance. At the procedure end, the model produces an estimate of ventricular volumes and Emaxl along with systemic and pulmonary pressures (output variables). The procedure has been tested using 4 sets of experimental data including left ventricular assist device assistance.&lt;/p&gt;&lt;p&gt;&lt;b&gt;RESULTS: &lt;/b&gt;The algorithm allows the reproduction of the circulatory conditions defined by all input variable sets, giving as well an estimate of output variables.&lt;/p&gt;&lt;p&gt;&lt;b&gt;CONCLUSIONS: &lt;/b&gt;The algorithm permits application of the model in environments where the simplicity of use and velocity of execution are of primary importance. Due to its modular structure, the model can be modified adding new circulatory districts or changing the existing ones. The model could also be applied in educational applications.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">12</style></issue><custom1><style face="normal" font="default" size="100%">https://www.ncbi.nlm.nih.gov/pubmed/19115196?dopt=Abstract</style></custom1></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Positano, Vincenzo</style></author><author><style face="normal" font="default" size="100%">Pingitore, Alessandro</style></author><author><style face="normal" font="default" size="100%">Giorgetti, Assuero</style></author><author><style face="normal" font="default" size="100%">Favilli, Brunella</style></author><author><style face="normal" font="default" size="100%">Santarelli, Maria Filomena</style></author><author><style face="normal" font="default" size="100%">Landini, Luigi</style></author><author><style face="normal" font="default" size="100%">Marzullo, Paolo</style></author><author><style face="normal" font="default" size="100%">Lombardi, Massimo</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A fast and effective method to assess myocardial necrosis by means of contrast magnetic resonance imaging.</style></title><secondary-title><style face="normal" font="default" size="100%">J Cardiovasc Magn Reson</style></secondary-title><alt-title><style face="normal" font="default" size="100%">J Cardiovasc Magn Reson</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Contrast Media</style></keyword><keyword><style  face="normal" font="default" size="100%">Gadolinium DTPA</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Image Enhancement</style></keyword><keyword><style  face="normal" font="default" size="100%">Image Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Magnetic Resonance Imaging, Cine</style></keyword><keyword><style  face="normal" font="default" size="100%">Middle Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Myocardium</style></keyword><keyword><style  face="normal" font="default" size="100%">Necrosis</style></keyword><keyword><style  face="normal" font="default" size="100%">Organophosphorus Compounds</style></keyword><keyword><style  face="normal" font="default" size="100%">Organotechnetium Compounds</style></keyword><keyword><style  face="normal" font="default" size="100%">Radiopharmaceuticals</style></keyword><keyword><style  face="normal" font="default" size="100%">Tomography, Emission-Computed, Single-Photon</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2005</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2005</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">7</style></volume><pages><style face="normal" font="default" size="100%">487-94</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;b&gt;PURPOSE: &lt;/b&gt;Contrast magnetic resonance (CMR) can identify myocardial necrosis after gadolinium administration as a hyperenhanced (HE) area. Yet there are no software tools that can effectively quantify such an area. The aim of this study is to develop a robust and effective algorithmic method for defining the extent of myocardial necrosis evidenced through CMR.&lt;/p&gt;&lt;p&gt;&lt;b&gt;METHOD: &lt;/b&gt;Fifteen patients with previous myocardial infarction underwent nitrate Tetrofosmin G-SPECT and CMR. A software tool was developed, allowing semiautomatic detection of endocardial and epicardial borders and the automatic detection of HE regions. The accuracy of the proposed quantitative method of analysis has been tested with G-SPECT analysis that it is less than an ideal method for assessing myocardial viability, but at present is accepted and widely used in the clinical arena.&lt;/p&gt;&lt;p&gt;&lt;b&gt;RESULTS: &lt;/b&gt;Segmental (SEHE) and global extension of HE were evaluated. HE was present in 161 of the 255 analyzed segments. Of the 161 HE segments, the mean SEHE was 36 +/- 30%. The operator independence (intraobserver: r = 0.97, p &lt; 0.0001, interobserver: r = 0.95, p &lt; 0.0001) was good and significant, with noticeable time savings with respect to manual analysis. There was strong and inverse correlation between SEHE and scintigraphic regional uptake reduction (r = -0.66, p &lt; 0.0001), and also a positive correlation between SEHE and SPECT defect extension (r = 0.75, p &lt; 0.0001). When assessing the global extent of necrosis, the correlation between the two techniques was strong (r = 0.79, p = 0.0004).&lt;/p&gt;&lt;p&gt;&lt;b&gt;CONCLUSIONS: &lt;/b&gt;The proposed method of quantifying myocardial necrosis by CMR is highly reliable, reproducible, and operator-independent for quantifying.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue><custom1><style face="normal" font="default" size="100%">https://www.ncbi.nlm.nih.gov/pubmed/15881533?dopt=Abstract</style></custom1></record></records></xml>