<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Positano, Vincenzo</style></author><author><style face="normal" font="default" size="100%">Pingitore, Alessandro</style></author><author><style face="normal" font="default" size="100%">Giorgetti, Assuero</style></author><author><style face="normal" font="default" size="100%">Favilli, Brunella</style></author><author><style face="normal" font="default" size="100%">Santarelli, Maria Filomena</style></author><author><style face="normal" font="default" size="100%">Landini, Luigi</style></author><author><style face="normal" font="default" size="100%">Marzullo, Paolo</style></author><author><style face="normal" font="default" size="100%">Lombardi, Massimo</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A fast and effective method to assess myocardial necrosis by means of contrast magnetic resonance imaging.</style></title><secondary-title><style face="normal" font="default" size="100%">J Cardiovasc Magn Reson</style></secondary-title><alt-title><style face="normal" font="default" size="100%">J Cardiovasc Magn Reson</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Contrast Media</style></keyword><keyword><style  face="normal" font="default" size="100%">Gadolinium DTPA</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Image Enhancement</style></keyword><keyword><style  face="normal" font="default" size="100%">Image Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Magnetic Resonance Imaging, Cine</style></keyword><keyword><style  face="normal" font="default" size="100%">Middle Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Myocardium</style></keyword><keyword><style  face="normal" font="default" size="100%">Necrosis</style></keyword><keyword><style  face="normal" font="default" size="100%">Organophosphorus Compounds</style></keyword><keyword><style  face="normal" font="default" size="100%">Organotechnetium Compounds</style></keyword><keyword><style  face="normal" font="default" size="100%">Radiopharmaceuticals</style></keyword><keyword><style  face="normal" font="default" size="100%">Tomography, Emission-Computed, Single-Photon</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2005</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2005</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">7</style></volume><pages><style face="normal" font="default" size="100%">487-94</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;b&gt;PURPOSE: &lt;/b&gt;Contrast magnetic resonance (CMR) can identify myocardial necrosis after gadolinium administration as a hyperenhanced (HE) area. Yet there are no software tools that can effectively quantify such an area. The aim of this study is to develop a robust and effective algorithmic method for defining the extent of myocardial necrosis evidenced through CMR.&lt;/p&gt;&lt;p&gt;&lt;b&gt;METHOD: &lt;/b&gt;Fifteen patients with previous myocardial infarction underwent nitrate Tetrofosmin G-SPECT and CMR. A software tool was developed, allowing semiautomatic detection of endocardial and epicardial borders and the automatic detection of HE regions. The accuracy of the proposed quantitative method of analysis has been tested with G-SPECT analysis that it is less than an ideal method for assessing myocardial viability, but at present is accepted and widely used in the clinical arena.&lt;/p&gt;&lt;p&gt;&lt;b&gt;RESULTS: &lt;/b&gt;Segmental (SEHE) and global extension of HE were evaluated. HE was present in 161 of the 255 analyzed segments. Of the 161 HE segments, the mean SEHE was 36 +/- 30%. The operator independence (intraobserver: r = 0.97, p &lt; 0.0001, interobserver: r = 0.95, p &lt; 0.0001) was good and significant, with noticeable time savings with respect to manual analysis. There was strong and inverse correlation between SEHE and scintigraphic regional uptake reduction (r = -0.66, p &lt; 0.0001), and also a positive correlation between SEHE and SPECT defect extension (r = 0.75, p &lt; 0.0001). When assessing the global extent of necrosis, the correlation between the two techniques was strong (r = 0.79, p = 0.0004).&lt;/p&gt;&lt;p&gt;&lt;b&gt;CONCLUSIONS: &lt;/b&gt;The proposed method of quantifying myocardial necrosis by CMR is highly reliable, reproducible, and operator-independent for quantifying.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue><custom1><style face="normal" font="default" size="100%">https://www.ncbi.nlm.nih.gov/pubmed/15881533?dopt=Abstract</style></custom1></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Taylor, C A</style></author><author><style face="normal" font="default" size="100%">Draney, M T</style></author><author><style face="normal" font="default" size="100%">Ku, J P</style></author><author><style face="normal" font="default" size="100%">Parker, D</style></author><author><style face="normal" font="default" size="100%">Steele, B N</style></author><author><style face="normal" font="default" size="100%">Wang, K</style></author><author><style face="normal" font="default" size="100%">Zarins, C K</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Predictive medicine: computational techniques in therapeutic decision-making.</style></title><secondary-title><style face="normal" font="default" size="100%">Comput Aided Surg</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Comput Aided Surg</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Arterial Occlusive Diseases</style></keyword><keyword><style  face="normal" font="default" size="100%">Blood Circulation</style></keyword><keyword><style  face="normal" font="default" size="100%">Cardiovascular Surgical Procedures</style></keyword><keyword><style  face="normal" font="default" size="100%">Computer Simulation</style></keyword><keyword><style  face="normal" font="default" size="100%">Diagnostic Imaging</style></keyword><keyword><style  face="normal" font="default" size="100%">Finite Element Analysis</style></keyword><keyword><style  face="normal" font="default" size="100%">Forecasting</style></keyword><keyword><style  face="normal" font="default" size="100%">Hemorheology</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Image Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Internet</style></keyword><keyword><style  face="normal" font="default" size="100%">Leg</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Middle Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Models, Anatomic</style></keyword><keyword><style  face="normal" font="default" size="100%">Models, Cardiovascular</style></keyword><keyword><style  face="normal" font="default" size="100%">Patient Care Planning</style></keyword><keyword><style  face="normal" font="default" size="100%">Peripheral Vascular Diseases</style></keyword><keyword><style  face="normal" font="default" size="100%">Software</style></keyword><keyword><style  face="normal" font="default" size="100%">Therapy, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Treatment Outcome</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">1999</style></year><pub-dates><date><style  face="normal" font="default" size="100%">1999</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://informahealthcare.com/doi/abs/10.3109/10929089909148176</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">4</style></volume><pages><style face="normal" font="default" size="100%">231-47</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;The current paradigm for surgery planning for the treatment of cardiovascular disease relies exclusively on diagnostic imaging data to define the present state of the patient, empirical data to evaluate the efficacy of prior treatments for similar patients, and the judgement of the surgeon to decide on a preferred treatment. The individual variability and inherent complexity of human biological systems is such that diagnostic imaging and empirical data alone are insufficient to predict the outcome of a given treatment for an individual patient. We propose a new paradigm of predictive medicine in which the physician utilizes computational tools to construct and evaluate a combined anatomic/physiologic model to predict the outcome of alternative treatment plans for an individual patient. The predictive medicine paradigm is implemented in a software system developed for Simulation-Based Medical Planning. This system provides an integrated set of tools to test hypotheses regarding the effect of alternate treatment plans on blood flow in the cardiovascular system of an individual patient. It combines an Internet-based user interface developed using Java and VRML, image segmentation, geometric solid modeling, automatic finite element mesh generation, computational fluid dynamics, and scientific visualization techniques. This system is applied to the evaluation of alternate, patient-specific treatments for a case of lower extremity occlusive cardiovascular disease.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">5</style></issue><custom1><style face="normal" font="default" size="100%">https://www.ncbi.nlm.nih.gov/pubmed/10581521?dopt=Abstract</style></custom1></record></records></xml>