<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Ferrari, G</style></author><author><style face="normal" font="default" size="100%">Kozarski, M</style></author><author><style face="normal" font="default" size="100%">Gu, Y J</style></author><author><style face="normal" font="default" size="100%">De Lazzari, C</style></author><author><style face="normal" font="default" size="100%">Di Molfetta, A</style></author><author><style face="normal" font="default" size="100%">Palko, K J</style></author><author><style face="normal" font="default" size="100%">Zieliński, K</style></author><author><style face="normal" font="default" size="100%">Górczynska, K</style></author><author><style face="normal" font="default" size="100%">Darowski, M</style></author><author><style face="normal" font="default" size="100%">Rakhorst, G</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Application of a user-friendly comprehensive circulatory model for estimation of hemodynamic and ventricular variables.</style></title><secondary-title><style face="normal" font="default" size="100%">Int J Artif Organs</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Int J Artif Organs</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Animals</style></keyword><keyword><style  face="normal" font="default" size="100%">Cardiac Pacing, Artificial</style></keyword><keyword><style  face="normal" font="default" size="100%">Cardiovascular Diseases</style></keyword><keyword><style  face="normal" font="default" size="100%">Elasticity</style></keyword><keyword><style  face="normal" font="default" size="100%">Hemodynamics</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Models, Cardiovascular</style></keyword><keyword><style  face="normal" font="default" size="100%">Reproducibility of Results</style></keyword><keyword><style  face="normal" font="default" size="100%">Ventricular Function</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2008 Dec</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">31</style></volume><pages><style face="normal" font="default" size="100%">1043-54</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;b&gt;PURPOSE: &lt;/b&gt;Application of a comprehensive, user-friendly, digital computer circulatory model to estimate hemodynamic and ventricular variables.&lt;/p&gt;&lt;p&gt;&lt;b&gt;METHODS: &lt;/b&gt;The closed-loop lumped parameter circulatory model represents the circulation at the level of large vessels. A variable elastance model reproduces ventricular ejection. The circulatory model has been modified embedding an algorithm able to adjust the model parameters reproducing specific circulatory conditions. The algorithm reads input variables: heart rate, aortic pressure, cardiac output, and left atrial pressure. After a preliminary estimate of circulatory parameters and ventricular elastance, it adjusts the amount of circulating blood, the value of the systemic peripheral resistance, left ventricular elastance, and ventricular rest volume. Input variables and the corresponding calculated variables are recursively compared: the procedure is stopped if the difference between input and calculated variables is within the set tolerance. At the procedure end, the model produces an estimate of ventricular volumes and Emaxl along with systemic and pulmonary pressures (output variables). The procedure has been tested using 4 sets of experimental data including left ventricular assist device assistance.&lt;/p&gt;&lt;p&gt;&lt;b&gt;RESULTS: &lt;/b&gt;The algorithm allows the reproduction of the circulatory conditions defined by all input variable sets, giving as well an estimate of output variables.&lt;/p&gt;&lt;p&gt;&lt;b&gt;CONCLUSIONS: &lt;/b&gt;The algorithm permits application of the model in environments where the simplicity of use and velocity of execution are of primary importance. Due to its modular structure, the model can be modified adding new circulatory districts or changing the existing ones. The model could also be applied in educational applications.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">12</style></issue><custom1><style face="normal" font="default" size="100%">https://www.ncbi.nlm.nih.gov/pubmed/19115196?dopt=Abstract</style></custom1></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Ferrari, G</style></author><author><style face="normal" font="default" size="100%">Kozarski, M</style></author><author><style face="normal" font="default" size="100%">De Lazzari, C</style></author><author><style face="normal" font="default" size="100%">Clemente, F</style></author><author><style face="normal" font="default" size="100%">Merolli, M</style></author><author><style face="normal" font="default" size="100%">Tosti, G</style></author><author><style face="normal" font="default" size="100%">Guaragno, M</style></author><author><style face="normal" font="default" size="100%">Mimmo, R</style></author><author><style face="normal" font="default" size="100%">Ambrosi, D</style></author><author><style face="normal" font="default" size="100%">Glapinski, J</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A hybrid (numerical-physical) model of the left ventricle.</style></title><secondary-title><style face="normal" font="default" size="100%">Int J Artif Organs</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Int J Artif Organs</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Heart Ventricles</style></keyword><keyword><style  face="normal" font="default" size="100%">Heart-Assist Devices</style></keyword><keyword><style  face="normal" font="default" size="100%">Hemodynamics</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Models, Cardiovascular</style></keyword><keyword><style  face="normal" font="default" size="100%">Models, Structural</style></keyword><keyword><style  face="normal" font="default" size="100%">Ventricular Function</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2001</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2001 Jul</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">24</style></volume><pages><style face="normal" font="default" size="100%">456-62</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Hydraulic models of the circulation are used to test mechanical devices and for training and research purposes; when compared to numerical models, however, they are not flexible enough and rather expensive. The solution proposed here is to merge the characteristics and the flexibility of numerical models with the functions of physical models. The result is a hybrid model with numerical and physical sections connected by an electro-hydraulic interface - which is to some extent the main problem since the numerical model can be easily changed or modified. The concept of hybrid model is applied to the representation of ventricular function by a variable elastance numerical model. This prototype is an open loop circuit and the physical section is built out of a reservoir (atrium) and a modified windkessel (arterial tree). The corresponding equations are solved numerically using the variables (atrial and arterial pressures) coming from the physical circuit. Ventricular output flow is the computed variable and is sent to a servo amplifier connected to a DC motor-gear pump system. The gear pump, behaving roughly as a flow source, is the interface to the physical circuit. Results obtained under different hemodynamic conditions demonstrate the behaviour of the ventricular model on the pressure-volume plane and the time course of output flow and arterial pressure.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">7</style></issue><custom1><style face="normal" font="default" size="100%">https://www.ncbi.nlm.nih.gov/pubmed/11510917?dopt=Abstract</style></custom1></record></records></xml>